Medicine Stability Testing Chamber

  • Model : MSTC-175 Series
  • Capacity : 175L / 275L / 375L / 475L / 800L / 1075L
  • Mode : Temperature & Humidty / Temperature, Humidity & Light / Temperature & Light
  • Humidity Range(RH) : 30 – 95%
  • Humidity Stability(RH) : ±3%RH

Share the product

Medicine Stability Testing Chamber Feature:

  1. Dual refrigeration system with imported compressor for longer service life.
  2. PID control and imported humidity sensor for precise temperature and humidity regulation.
  3. Over-temperature alarm stops operation and triggers audible/visual alerts when limits are exceeded.
  4. Large LCD screen displays multiple data points simultaneously.
  5. Multi-segment programmable control for temperature and humidity with customizable cycles.

Medicine Stability Testing Chamber Specifications:

Model MSTC-175HT / MSTC-175HTI MSTC-175L / MSTC-175LI MSTC-175TL
  MSTC-275HT / MSTC-275HTI MSTC-275L / MSTC-275LI MSTC-275TL
  MSTC-375HT / MSTC-375HTI MSTC-375L / MSTC-375LI MSTC-375TL
  MSTC-475HT / MSTC-475HTI MSTC-475L / MSTC-475LI MSTC-475TL
  MSTC-800HT / MSTC-800HTI MSTC-800L / MSTC-800LI MSTC-800TL
  MSTC-1075HT / MSTC-1075HTI MSTC-1075L / MSTC-1075LI MSTC-1075TL
Mode Temperature & Humidity Temperature, Humidity & Light Temperature & Light
Temperature Range 0~65℃ WithoutIllumination: 4~50℃
Temperature Fluctuation High ±0.5℃, Low ±2℃
Temperature Uniformity ±2℃
Humidity Range(RH) 30 – 95% /
Humidity Stability(RH) ±3%RH /
Temperature Resolution 0.1℃
Illumination / 0 – 6000Lux adjustable
Illumination Difference / ≤ ±500Lux
Timing Range 1 – 99 hours/period
Temp.and Humidity Adjusting Balance temperature and humidity adjusting Balance temperature adjusting
Cooling System Imported compressor
Sensor PT100Capacitance sensor PT100
Ambient Temperature RT+5~30℃
Power Supply AC220V±10%, 50HZ
Power Rating(W) 1400/1950/2600/2800/3000/3200 1650/2200/2700/2900/3100/3300 1300/1750/2400/2600/2700/2800
Chamber Volume(L) 175/275/375/475/800/1075
Shelf 3
Printer Yes
Safety Device Compressor overheating and overpressureprotection, Fan overheating protection, Overtemperature protection, Overload protection, water shortageprotection
Chamber Size (WxDxH) (mm) 450x420x930, 580x510x935, 590x550x1160, 700x550x1250, 965x610x1370, 950×700×1600
N.W./G.W. MSTC-175HT: 178kg/232kg MSTC-175L: 182kg/237kg MSTC-175TL: 178kg/203kg
MSTC-275HT: 210kg/285kg MSTC-275L: 210kg/260kg MSTC-275TL: 210kg/260kg
MSTC-375HT: 249kg/283kg MSTC-375L: 249kg/283kg MSTC-375TL: 249kg/283kg
MSTC-475HT: 295kg/358kg MSTC-475L: 295kg/358kg MSTC-475TL: 295kg/358kg
MSTC-800HT: 360kg/468kg MSTC-800L: 360kg/465kg MSTC-800TL: 360kg/468kg
MSTC-1075HT: 470kg/586kg MSTC-1075L: 470kg/586kg MSTC-1075TL: 470kg/586kg
MSTC-175HTI: 178kg/203kg MSTC-175LI: 178kg/203kg
MSTC-275HTI: 210kg/260kg MSTC-275LI: 210kg/260kg
MSTC-375HTI: 249kg/283kg MSTC-375LI: 249kg/283kg
MSTC-475HTI: 295kg/358kg MSTC-475LI: 295kg/358kg
MSTC-800HTI: 360kg/468kg MSTC-800LI: 360kg/468kg
MSTC-1075HTI: 470kg/586kg MSTC-1075LI: 470kg/586kg
Shipping Size (WxDxH)(mm) MSTC-175HT: 750x1860x840 MSTC-175L: 750x1860x840 MSTC-175TL: 840x740x1880
MSTC-275HT: 880x1010x1860 MSTC-275L: 880x1010x1860 MSTC-275TL: 880x1010x1860
MSTC-375HT: 870x980x2080 MSTC-375L: 870x980x2080 MSTC-375TL: 870x980x2080
MSTC-475HT: 1010x1000x2250 MSTC-475L: 1010x1000x2250 MSTC-475TL: 1010x1000x2250
MSTC-800HT: 1250x1030x2300 MSTC-800L: 1250x1040x2300 MSTC-800TL: 1250x1030x2300
MSTC-1075HT:1200x1100x2550 MSTC-1075L: 1200x1100x2550 MSTC-1075TL: 1200x1100x2550
MSTC-175HTI: 840x740x1880 MSTC-175LI: 840x740x1880
MSTC-275HTI: 880x1010x1860 MSTC-275LI: 880x1010x1860
MSTC-375HTI: 870x980x2080 MSTC-375LI: 870x980x2080
MSTC-475HTI: 1010x1000x2250 MSTC-475LI: 1010x1000x2250
MSTC-800HTI: 1250x1030x2300 MSTC-800LI: 1250x1030x2280
MSTC-1075HTI: 1200x1100x2550 MSTC-1075LI: 1200x1100x2550

WHY SCITEK

  1. 36 Months Limited Warranty
  2. CE & FDA Standards
  3. 1-2 Days Handling and 7-30 Days Shipping

Title

CONTACT INFO

Xuegu Huigu Science and Technology Park, Xiqing District, Tianjin

Phone: +86-531-82893797

Go to Top